Description
APPLICATION:
The 6-way flow diverter is used to connect or exclude flow to two uses using a single power supply.
A single lever, by means of a mechanical coupling, operates two sections simultaneously.
This particular configuration is also suitable for the operation of two single-acting actuators.
MOUNTING AND OPERATION:
Connect the power supply to the P and P1 ports and the ports A, B and A1 , B2 to the actuator
Type B (Closed center): with the lever in central position all the openings are closed (allowed leakage content).
Type F (open center): with the lever in the central position all the openings are connected.
Turning the lever to position 1 allows flow the ports A and A1 .
Turning the lever to position 2 allows flow the openings B and B1 .