Description
APPLICATION:
The use of double acting overcenter valve flangeable type is to control and lock the movement of an actuator in both direction.
It guarantees the stopping of the flow, the controlled descent of the load preventing cavitation, protects the circuit from pressure increases and allows free passage in the opposite direction.
Thanks to the flange connections it is possible to mount it directly on the actuator.
MOUNTING AND OPERATION:
Connect the V1 and V2 ports to the power supply, flange C1 and C2 to the actuator.
Setting must be 30% higher than the pressure induced by the load.
UPON REQUEST:
Special zinc plating – Steel cap – Setting.