Description
APPLICATION:
The dual cross over relief valve is made with two pressure relief valves.
The use of this valve is to limit the pressure on both connecting lines.
MOUNTING AND OPERATION:
Connect an actuator and a power supply to V2 port and an actuator and a power supply to V1 port.
The pressure at V1 port connects the actuator while excess pressure is released to V2 port.
Valve 1 is used to adjust the maximum pressure on ports V2.
The pressure of the V1 port can be measured by replacing the
cap M1 with a pressure gauge.
Vice versa, the same operation is obtained for the V1 ports by
acting on the valve 2.
The pressure regulation is sensitive to possible counter pressures on the tank line.
The adjustment operation must only be carried out within the setting range of the spring.
UPON REQUEST:
Adjustment – Hand knob – Lockwire – Steel cap.